PORTABLE STAGING:
STAGE
• Type:
• Size:
• Height:
• Stair Units:
• Truck Ramps:
• Skirting:
• Railings:
• Barricade:
StageRight M.E. 1000 System
Main Stage: 32-feet wide by 24-feet deep (size can be customized to meet needs)
4-feet High
(2) 4' portable stair units with lights
Two (2) 15-feet 7-inches long by 3-feet 2-inches wide
Donstage and side of stage coverage available
As needed
Mojo-type
• 56-feet set 4-feet from downstage edge
• 24-feet 6-inches set on stage side of FOH Mix (If requested)
To download a PDf version of the stage please click the icon below.
PORTABLE STAGE RISERS:
STAGE RISERS
• Type:
• Size:
• Surface:
• Height:
• Stair Units:
• Skirting:
Stage Right Z-800HD
Standard 8' x 8' x 1' to 2'h drum risers in house
Carpet or techstage
Rolling Risers must be outsourced.
Available upon request
Available upon request
STAGE & SHORE POWER:
STAGE POWER
• 2 disconnects - each 400A 3 phase WYE 208V
• 4 disconnects - each 200A 3 phase WYE 208V
Additional service with Safety-Cam set-up
• 3 disconnects - each 400A 3 phase WYE 208V
• 1 disconnect - 400A 3 phase WYE 480V
All service is 5 wire. Water pipe or ground rod available at disconnects.
Service located 90' from upstage center (typical).
SHORE POWER
• 2 disconnects - each 400A 3 phase WYE 208V
• 1 disconnects - each 200A 3 phase WYE 208V
LIGHTING:
• PERMANENT LIGHTING SYSTEM:
• House lights:
• LED lights used to light ceiling fabric for walk-in, intermissions and blow-out.
• Incandescent lighting along perimeter wall and stairwells
(must remain on during shows per fire code).
• STAGE PRODUCTION LIGHTING SYSTEM:
• Spot Lights
• Two (2) 1k Strong Cantos spotlights
• Located at FOH Mix on two 8'x4'x6' platforms left and right of center
• Portable Stage Lighting
• Fifteen (15) sticks of 93" double hung truss with 6-bars
• One-Hundred (100) Source 4 Par lighting fixtures with 575w lamps, gel frames and P&G pin connectors
• Thirty-Six (36) Source 4 Ellipsoidal lighting fixtures with 575w lamps gel frames and P&G pin connectors
• 150 channels of 1.2 kw dimming in road cases
• Power Distribution system
• System included - Socapex cables, mega-clamps, and Six (6) Fan-outs.
• Standard Lighting Plot
• Upstage Lighting Truss set 20-feet upstage of the downstage edge with (3) sticks of double hung 6bar Pars
• Midstage Lighting Truss set 8-feet upstage of the downstage edge with (3) sticks of double hung 6bar Pars
• FOH Lighting Truss set 11-feet downstage of the downstage edge with (1) stick of double hung 6bar Pars and (2) sticks of 19degree single hung 6bar ellipsoidals.
AUDIO:
• PROFESSIONAL SOUND REINFORCEMENT SYSTEM:
• Console
• Midas M32 Digital Mixing Console
• Speakers:
• Twelve (12) ElectroVoice XLC127DVX Line Array speakers hung six (6) per side with XLD Grid
• Two (2) ElectroVoice QRx-115/75 speakers for side fills
• Two (2) ElectroVoice Xi-1082 speakers for front fills
• Eight (8) EAW LA400 sub-woofer speakers, stackable 4-per side.
• Portable Amplifier/EQ racks; Speakon speaker cable; power distribution system included with package.
• PROFESSIONAL MONITOR MIX SYSTEM:
• Console
• Midas Sienna 48 Mixing Console
• Speakers:
• Six (6) Yamaha SM15 Stage Monitors
• Eight (8) RCF Dual 18” Speaker
• One (1) JBL Drum Fill
• Stage power distribution system included with package.
• For Audio Questions please contact:
Qrowe Productions LLC
700 Evergreen Street
Norway, IA 52318
319-929-4755
qrowe@aol.com
• Microphones / Microphone Stands / Packages available as needed.
• Hearing Assistance:
• LISTEN LT-800-072 Transmitter with Mic or Line level inputs RCA, ¼-inch and XLR connectors.
• Fifty (50) LISTEN LR-300-072 Portable Digital FM Receivers (72 MHz)
• Intercom:
• Clearcom SB704 4 Channel Switchboard Main Station
• Three (3) Clear-Com RM704 Remote Intercom Stations, 4 Channel | Full Compass
• Two (2) Clearcom Belt Packs with Double Muff standard Headsets
• Eight (8) Clearcom Belt Packs with Single Muff standard headsets
• Two (2) Clearcom Belt Packs with a single-ear, 300-Ohm ultra-lightweight (1.3 oz) Headsets
• Two (2) Clearcom Handsets
• Four (4) Wireless Clearcom Handsets and belt packs and bases.
RIGGING:
• RIGGING GRID:
• Rigging grid is 80-feet wide by 136-feet long starting from center on the upstage (east) end of the building
• Grid is comprised of Five (5) primary rigging beams running up/down stage in an end-stage configuration.
• 250,000 pounds maximum capacity with 10,000 pounds per span
• Floor to bottom of the beams is 70-feet
• 2,500 lbs. per vertical point not to exceed 10,000 pounds per span
• 5,000 lbs. horizontal maximum pull per span
• 11,180 lbs. Tension maximum pull per span.
Click the PDF Icon Above to Download a PDF Map Showing Rigging Grid Information
• RIGGING INFORMATION:
• Minimum of two (2) High riggers and one (1) Ground required for all rigs.
• Steel Grid is easily accessible - cherry picker not necessary.
• Building does not supply wire rope or shackles.
• RIGGING EQUIPMENT:
• Eight (8) 1-Ton CM Lodestar Chain Hoists
• Eight (8) 1/2 - Ton CM Lodestar Chain Hoists
• Eight (8) sticks of 12”x12”x10’ Box Truss
• Four (4) sticks of 12"x12"x5' Box Truss
• Four (4) Five-way 12"x12" Box Truss Corners
• Twenty (20) sticks of 12"x12"x10' Triangle Truss
• Quantity of 5', 10' and 20' 3/8 Rigging steel, 5/8 shackles and round-slings
• Quantity of Motor Control Cable and two (2) Motor Control consoles.
PYROTECHNICS:
• Any show using pyrotechnic effects will be required to submit a detailed effects plot, along with a listing of effect details (placement, weight of charge, direction, and size of effect, ect.) Additionally, a current pyro technician’s license for the lead pyro technician valid for the largest classification of effect used, and MSDS sheets must be received by the Alliant Energy PowerHouse Event Manager at least 14 business days prior to the scheduled load-in date. The Alliant Energy PowerHouse reserves the right to require a walk through inspection or full demonstration of the effects in the presence of the local Fire Inspector for any pyrotechnic display.
DRESSING ROOMS / LAUNDRY:
• DRESSING / TEAM ROOMS:
• All dressing rooms are located on the North side on the main floor (stage left in an end-stage configuration)
• Star Dressing Room 1:
• Approximately 232 square feet of space with Lockers, 2-Stall Restroom, 2-Showers, 2-Hand Sinks, and Counter Top with Makeup Mirror.
• Star Dressing Room 2:
• Approximately 84 square foot hallway with two private dressing rooms.
• Dressing room A - 95 square feet with Counter top and Makeup Mirror, 1-Stall Restroom with sink and shower.
• Dressing room B - 110 square feet with Counter top and Makeup Mirror, 1-Stall Restroom with sink and shower.
• Locker Room A:
• Locker Room with Private Coaches Office
• Locker Room - 565 square feet locker room with 19-Lockers, White Boards, a Full Length Mirror, 2-Stall Restroom with 3-Sinks / Mirrors sets and 4-Showers.
• Coaches Office - 100 square feet with Five (5) Lockers, 1-Stall Restroom with sink and shower.
• Locker Room B:
• Locker Room with Private Coaches Office
• Locker Room - 630 square feet locker room with 21-Lockers, White Board, a Full Length Mirror, 2-Stall Restroom with 3-Sinks / Mirrors sets and 4-Showers.
• Coaches Office - 100 square feet with Five (5) Lockers, 1-Stall Restroom with sink and shower.
• Locker Room C:
• Locker Room with Private Coaches Office
• Locker Room - 630 square feet locker room with 21-Lockers, White Board, a Full Length Mirror, 2-Stall Restroom with 3-Sinks / Mirrors sets and 4-Showers.
• Coaches Office - 100 square feet with Five (5) Lockers, 1-Stall Restroom with sink and shower.
• Locker Room D:
• Locker Room with Private Coaches Office
• Locker Room - 565 square feet locker room with 19-Lockers, White Boards, a Full Length Mirror, 2-Stall Restroom with 3-Sinks / Mirrors sets and 4-Showers.
• Coaches Office - 100 square feet with Five (5) Lockers, 1-Stall Restroom with sink and shower.
• Furniture, plants, and other miscellaneous rentals can be arranged through the Event Manager.
• LAUNDRY ROOM:
Click the PDF Icon Above to Download a PDF Map Showing Dressing Room Information
LOADING DOCKS / FORKLIFTS / PARKING:
• LOADING DOCKS:
• The Loading Docks are located on the North side of the Alliant Energy PowerHouse Complex located off A Avenue. The loading dock area can accommodate Three (3) 53-foot semi-tractor-trailers at one time. Two additional low truck docks are located West of the three main loading docks.
• Loading Dock Equipment:
• Two (2) Aluminum Truck Ramps
• One (1) Dock Plate
• Dock C has a Trailer Lock to allow forklift to be driven into trailer.
• Quantity of Orange Road Cones are available.
• FORKLIFTS & GENIE LIFT:
• Two (2) 4,500 lbs. Forklifts with One (1) set of Fork Extensions.
• One (1) Genie Lift AWP-40s with 46-foot Working Height.
• PARKING:
• Parking for up to Four (4) Tour Buses close to shore power with additional room for two (2) more with lane closure on A Avenue.
• Parking for up to Three (3) 53-foot semi-tractor-trailers - Two (2) in loading dock and one (1) on A Avenue.
• Additional Street Parking on 2nd Street. Street parking at hooded meters can be reserved by contacting the Event manager 1-week in advance. Standard bagged meter cost is $10.00 per meter with a $25.00 hooding/un-hooding fee per every ten (10) meters.